Environmental Sensors
-
Liquid detection sensor for IPDU-Sx, x = water sensor cable, y = 2-wire cable
For warning of flooding. 100% waterproof electronics. Detects any conductive liquid. Puddle: 0.6" (15 mm) diameter. Detects liquid depth >0.1" (2.5 mm).
-
Smoke Detection Sensor, CE Approved
Photoelectric smoke detector
-
Temperature sensor for ENVIROMUX-SEMS-16 or IPDU-Sx
Temperature Sensor. Applications from 32°F to 122°F (0°C to 50°C). Re-calibration is not necessary after initial set-up.
-
Humidity sensor for ENVIROMUX-SEMS-16 or IPDU-Sx
Humidity Sensor. Applications from 20 to 80% relative humidity at temperatures between 32°F and 104°F (0°C to 40°C. Re-calibration is not necessary after initial set-up.
-
Temperature/humidity sensor for ENVIROMUX-SEMS-16 or IPDU-Sx
Temperature/Humidity Sensor. Applications from 32°F to 122°F (0°C to 50°C) and 20 to 80% relative humidity. Re-calibration is not necessary after initial set-up.
-
Temperature/wide range humidity sensor for ENVIROMUX-SEMS-16 or IPDU-Sx
Temperature/Wide Range Humidity Sensor. Detect humidity from 32°F to 122°F . Wide Range humidity readings accurate to ±3% for 20 to 80% relative humidity .
-
Precision humidity sensor for ENVIROMUX-SEMS-16
NIST certified accurate to within ±1% from 10 to 80% relative humidity at 77°F to 95°F (25°C to 35°C). Two-point field calibration. Output: 4-20 mA DC = 0 to 100% RH.
-
Precision temperature/humidity sensor for ENVIROMUX-SEMS-16, 20°F to 120°F
Applications from 20°F to 120°F (-6°C to 48°C). Temperature accurate to within ± 1.50%. NIST traceable calibration accurate to within ±1% from 10 to 80% relative humidity at 77°F to 95°F (25°C to 35°C). Uses a platinum RTD for precision temperature compensation.
-
Precision temperature/humidity sensor for ENVIROMUX-SEMS-16, -20 to 140°F
Applications from -20 to 140°F (-28 to 60°C). Temperature accurate to within ± 1.50%. NIST traceable calibration accurate to within ±1% from 10 to 80% relative humidity at 77 to 95°F (25 to 35°C). Uses a platinum RTD for precision temperature compensation.
-
Precision temperature/humidity sensor for ENVIROMUX-SEMS-16, 30 to 180°F
Applications from 30°F to 180°F (-1°C to 82°C). Temperature accurate to within ± 1.50%. NIST traceable calibration accurate to within ±1% from 10 to 80% relative humidity at 77°F to 95°F (25°C to 35°C). Uses a platinum RTD for precision temperature compensation.
-
Wall mount temperature/humidity sensor for ENVIROMUX-SEMS-16
Wall Mount Temperature/Humidity Sensor. Applications from 23 F to 131 F (-5 C to 55 C) and 10 to 90% relative humidity. Re-calibration is not necessary after initial set-up.
-
Duct mount temperature/humidity sensor for ENVIROMUX-SEMS-16
Duct Mount Temperature/Humidity Sensor. Applications from 14 F to 140 F (-10 C to 60 C) and 10 to 90% relative humidity. Re-calibration is not necessary after initial set-up.
-
Pipe Temperature Sensor
Pipe Temperature Sensor with lengths from 1 ft. to up to 1000 ft. of CAT5E Cable
-
Outdoor Temperature sensor for ENVIROMUX-SEMS-16
Outdoor Temperature Sensor. Applications from -40°F to 185°F (-40°C to 85°C). Weatherproof enclosure designed to IP67 specifications.
-
Smoke detection sensor for ENVIROMUX-SEMS-16
Smoke Detection Sensor. Photoelectric smoke detector. Built-in 135° F (57° C) thermal heat sensor.
-
Liquid detection sensor for ENVIROMUX-SEMS-16, x = water sensor cable, y = 2-wire cable
For warning of flooding. Detects liquid depth >0.1" (2.5 mm) . Minimum puddle: 0.6" (15 mm) diameter. 100% waterproof electronics. Detects any liquid, except deionized water. RJ45 connector. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m) .
-
Air Velocity Sensor for ENVIROMUX Monitoring Systems
Reliable mechanical solution for monitoring air flow. Dust resistant design. Requires the ENVIROMUX-S5VDC sensor converter to operate.
-
Carbon monoxide detector for ENVIROMUX-SEMS-16
Continuous air monitoring. Pre-set alarm points alert at:70 ppm after 60 to 240 minutes. 150 ppm after 10 to 50 minutes. 400 ppm after 4 to 15 minutes.
-
4-20 mA sensor converter for ENVIROMUX-SEMS-16
4-20 mA Sensor Converter. External RJ45 device monitors up to two 4-20 mA analog sensors. Supports ISA Type 2, ISA Type 3, and ISA Type 4 sensors.
-
5VDC sensor converter for ENVIROMUX-SEMS-16
5 V DC Sensor Converter. External RJ45 device monitors up to two linear DC sensors, 0 ~ 5 V DC. 8-position Screw Terminal. Compatible with ENVIROMUX-SEMS-16 only.
-
Sensor Extension Cables
Connect dry contact sensors to the ENVIROMUX-SEMS-16